WANG Yong-gen , CHEN Shu-sha , WANG Jian-bo . Determination of Ammonium Nitrogen in Medical Organization Sewage by On-line Dialysis with Ion Chromatography[J]. Journal of Environmental and Occupational Medicine, 2012, 29(1): 34-36.
Citation: WANG Yong-gen , CHEN Shu-sha , WANG Jian-bo . Determination of Ammonium Nitrogen in Medical Organization Sewage by On-line Dialysis with Ion Chromatography[J]. Journal of Environmental and Occupational Medicine, 2012, 29(1): 34-36.

Determination of Ammonium Nitrogen in Medical Organization Sewage by On-line Dialysis with Ion Chromatography

  • Objective To establish an ion chromatography method for the simple and rapid analysis of ammonium nitrogen in medical organization sewage.

    Methods After a certain amount of samples diluted to volume with ultrapure water, on-line dialysis was developed for the solution pretreatment.

    Results The linear range of this method was 0.20-20 mg/L with the correlation coefficient r > 0.999 9. The detection limit of NH4+-N was 0.018 mg/L, the relative standard deviation (RSD) was less than 3.0%, and the recovery was between 96.2% and 100.1%.

    Conclusion The on-line dialysis pretreatment can effectively eliminate organic and other interfering substances to purify the samples. It is a quick and simple method to determine the ammonium nitrogen in medical organization sewage.