JIANG Yuan , ZHAO Li-li , GUI Xiao-hong , WU Jie , GUO Jun-tao , LI Jing , ZHANG Yang-yi , WANG Li-li , YU Chen-lei , SHEN Xin , WAN Kang-lin , MEI Jian . Application Evaluation on BACTEC MGIT 960 System for Drug Susceptibility Testing of Mycobacterium Tuberculosis[J]. Journal of Environmental and Occupational Medicine, 2013, 30(3): 202-204.
Citation: JIANG Yuan , ZHAO Li-li , GUI Xiao-hong , WU Jie , GUO Jun-tao , LI Jing , ZHANG Yang-yi , WANG Li-li , YU Chen-lei , SHEN Xin , WAN Kang-lin , MEI Jian . Application Evaluation on BACTEC MGIT 960 System for Drug Susceptibility Testing of Mycobacterium Tuberculosis[J]. Journal of Environmental and Occupational Medicine, 2013, 30(3): 202-204.

Application Evaluation on BACTEC MGIT 960 System for Drug Susceptibility Testing of Mycobacterium Tuberculosis

More Information
  • Corresponding author:

    MEI Jian ,Email:meijiansh@yahoo.com.cn

  • Received Date: August 02, 2012
  • [Objective] To evaluate the reliability of BACTEC MGIT 960 in testing susceptibilities of Mycobacterium tuberculosis to 8 tuberculosis (TB) medicines for first-line and second-line treatment.

    [Methods] The susceptibilities of 8 firstline and second-line anti-tuberculosis drugs, including isoniazid (INH), rifampicin (RFP), streptomycin (SM), ethambutol (EMB), capreomycin (CPM), kanamycin (KAN), ofloxacin (OFLX), and ethionamide (ETH), were tested by BACTEC MGIT 960 system, and the results (average time of reporting results and rater agreement) were compared with those obtained by the traditional L-J proportion method. Statistical analysis was performed using paired t test and Kappa test.

    [Results] The agreement rates of the 4 first-line drugs, INH, RFP, SM, and EMB, tested by MGIT 960 and L-J proportion method were 98.0% (198/202), 96.5% (195/202), 94.1% (190/202), and 83.7% (169/202), respectively. The agreement rates of the 4 second-line drugs, CPM, KAN, OFLX, and ETH, were 87.0% (67/77), 93.5% (72/77), 97.4% (75/77) and 68.8% (53/77), respectively. The medians of drug susceptibility testing durations using MGIT 960 were 11 days for the first-line drugs and 8 days for the second-line drugs, respectively; while the medians using L-J proportion method were both 28 days for the first-line and the second-line drugs (P < 0.01).

    [Conclusion] The BACTEC MGIT 960 system is an accurate and rapid method to test the susceptibilities of Mycobacterium tuberculosis to first-line and the second-line drugs, and applicable to early diagnosis and treatment of drug-resistant TB.

  • Related Articles

    [1]ZHANG Bao, SUN Jin-hai. Sedentary behavior evaluation system for offce workers based on Delphi method[J]. Journal of Environmental and Occupational Medicine, 2018, 35(5): 434-437. DOI: 10.13213/j.cnki.jeom.2018.17653
    [2]LIU Lei, LI Peng-fei, PENG Yang-yang, TANG Kun, CHENG Tingting, PENG Xiao-ping. Application of risk assessment method and literature analogy method to pre-assessment of occupational hazards in waste-to-energy projects[J]. Journal of Environmental and Occupational Medicine, 2018, 35(4): 341-346. DOI: 10.13213/j.cnki.jeom.2018.17337
    [3]LI Jing , JIANG Yuan , ZHANG Yang-yi , WANG Li-li , WU Jie , YU Chen-lei , ZHU Guo-feng , SHEN Xin . Evaluation of Immunochromatogaphic Assays for Rapid Identification of Mycobacterium tuberculosis Complex from Liquid Culture[J]. Journal of Environmental and Occupational Medicine, 2015, 32(10): 974-978. DOI: 10.13213/j.cnki.jeom.2015.15164
    [4]SUN Yu-li , DONG Cheng , HONG Xinyu , SHUAI Yi , XIAO Ping . Comparison Study on Four Acute Oral Toxicity Testing Methods[J]. Journal of Environmental and Occupational Medicine, 2015, 32(6): 539-543. DOI: 10.13213/j.cnki.jeom.2015.15265
    [5]TAN Li-feng , SUN Xi-ling , XU Qiang-qiang , ZHAI Cheng-kai . Application of Delphi Method to Establishment of Evaluation Indicator System for Healthy Canteens[J]. Journal of Environmental and Occupational Medicine, 2014, 31(7): 548-551. DOI: 10.13213/j.cnki.jeom.2014.0130
    [6]ZHU Xiu-ying , SHI Ji-feng , FAN Zhong-fei , MIAO Jia-kui , GUO Ai-ping , ZOU Tao , CHEN Xiao-ling . Quantitative Evaluation Index System for Central Air Conditioning Hygiene by Delphi Method[J]. Journal of Environmental and Occupational Medicine, 2014, 31(4): 288-291. DOI: 10.13213/j.cnki.jeom.2014.0066
    [7]SU Yi , LI Zhu , WU Li-ming . Application of Delphi Method to the Screening of Hygienic Indicators for Household Water Purify Systems[J]. Journal of Environmental and Occupational Medicine, 2013, 30(6): 434-437.
    [8]DING Jin-fei , TAN Li-feng , TANG Zai-xiang , SHEN Yue-Ping . Delphi Method in Public Health: A Review of Its Application and Prospect[J]. Journal of Environmental and Occupational Medicine, 2012, 29(11): 727-730.
    [9]HUANG Lihong , CHEN Ren-jie , WU Chuan , WANG Li-fang , CHENG De-guang , SONG Wei-min . An Improved Integrated Index Method for Evaluating Piped Drinking Water Quality[J]. Journal of Environmental and Occupational Medicine, 2011, 28(3): 129-132.
    [10]JIN Hui , LIU Pei . Accuracy Evaluation of Diagnostic Test in the Absence of a Gold Standard Based on Latent Class Method[J]. Journal of Environmental and Occupational Medicine, 2010, 27(12): 735-738.

Catalog

    Article views (2643) PDF downloads (603) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return